01
High-Temperature Smoke Exhaust Fan - HTF Series Fire Protection Solution from China Suppliers & Factory
Parameters
| Model | Speed(r/min) | Power(kW) | Traffic(m³/h) | Total Pressure(Pa) | NoisedB(A) |
|---|---|---|---|---|---|
| 3.5 | 2900 | 0.75 | 4225–3350 | 280–420 | ≤78 |
| 4 | 2900 | 1.5 | 5500–3800 | 300–450 | ≤79 |
| 4.5 | 2900 | 2.2 | 8500–6210 | 410–670 | ≤84 |
| 5 | 2900 | 3 | 9824–6817 | 510–752 | ≤86 |
| 5.5 | 2900 | 4 | 15200–10900 | 398–621 | ≤86 |
| 6 | 2900 | 5.5 | 16090–13197 | 510–760 | ≤86 |
| 6.5 | 1450 | 5.5 | 21500–15300 | 425–680 | ≤88 |
| 7 | 1450 | 7.5 | 24380–18908 | 610–728 | ≤88 |
| 8 | 1450 | 7.5 | 31421–26012 | 600–723 | ≤89 |
| 9 | 1450 | 11 | 33510–27613 | 562–840 | ≤89 |
| 10 | 1450 | 11 | 45697–35000 | 630–770 | ≤90 |
| 11 | 1450 | 15 | 51552–48500 | 580–690 | ≤92 |
| 12 | 960 | 18.5 | 62763–55651 | 624–740 | ≤93 |
| 13 | 960 | 18.5 | 74708–56031 | 600–807 | ≤94 |
| 15 | 960 | 22 | 93800–76041 | 623–819 | ≤95 |
| HTF-Ⅱ Main Technical Parameters | |||||
| 5 | 2900 | 3/2.5 | 9824–6817 | 510–752 | ≤80 |
| 1450 | 3/25 | 4912–3410 | 127–1B8 | ≤75 | |
| 5.5 | 2900 | 4/3.3 | 15200–10900 | 398–621 | ≤86 |
| 1450 | 4/3.3 | 7600–5450 | 100–155 | ≤75 | |
| 6 | 2900 | 5.5/4.5 | 16090–13197 | 510–760 | ≤86 |
| 1450 | 5.5/4.5 | 8045–6599 | 127–190 | ≤75 | |
| 6.5 | 1450 | 5.5/4 | 21500–15300 | 425–680 | ≤88 |
| 960 | 5.5/4 | 14235–10130 | 187–298 | ≤80 | |
| 7 | 1450 | 8/6.5 | 24380–18908 | 610–728 | ≤88 |
| 960 | 8/6.5 | 16141–12518 | 267–319 | ≤80 | |
| 8 | 1450 | 8/6.5 | 31421–20012 | 600–723 | ≤89 |
| 960 | 8/6.5 | 20800–17222 | 263–317 | ≤80 | |
| 9 | 1450 | 11/9 | 33510–27513 | 562–840 | ≤90 |
| 960 | 11/9 | 22186–18216 | 246–368 | ≤81 | |
| 10 | 1450 | 11/9 | 45679–35000 | 630–770 | ≤90 |
| 960 | 16/13 | 30255–24019 | 276–338 | ≤80 | |
| 11 | 1450 | 16/13 | 51552–48500 | 580–690 | ≤92 |
| 960 | 16/13 | 38664–36376 | 326–387 | ≤83 | |
| 12 | 960 | 17/8 | 62763–55651 | 624–740 | ≤93 |
| 720 | 17/8 | 47072–43311 | 351–416 | ≤84 | |
| 13 | 960 | 17/8 | 74708–56031 | 600–807 | ≤94 |
| 720 | 17/8 | 56031–42023 | 338–454 | ≤84 | |
| 15 | 960 | 22/11 | 83800–76041 | 623–819 | ≤95 |
| 720 | 22/11 | 70350–57031 | 350–461 | ≤85 | |
HTF series fire-fighting high-temperature fan is a new product that has been optimized and developed, and is designed to meet the ventilation needs in high-temperature environments. The fan has an efficient performance curve and stable operating characteristics, which can effectively save energy and reduce operating costs. The powerful combination of its motor and transmission system makes the fan perform well in many occasions such as high-rise buildings, drying furnaces, underground garages and tunnels.
The HTF series fans adopt a fast start-stop design, which can flexibly adjust the air volume according to different usage requirements, ensuring that high-temperature smoke can be quickly discharged when a fire occurs, ensuring the safety of personnel and property. Its high-temperature smoke exhaust capability makes it an important part of the fire protection system, which can effectively cope with the challenges brought by fire.
The fan has a reasonable structural design, which is easy to install and maintain. Users can easily perform daily maintenance to ensure that the equipment is always in the best working condition. The high temperature resistant materials and advanced manufacturing process of the HTF series fan ensure its stability and reliability in extreme environments and are suitable for long-term operation.
The wide applicability of the HTF series fans makes them an ideal choice for high-rise buildings, industrial facilities and public places. Whether in the high temperature environment of a drying furnace or in the ventilation needs of an underground garage, the HTF series fans can provide excellent performance and help create a safe and comfortable working and living environment. In short, the HTF series fire high temperature fan is a high-quality ventilation equipment that integrates high efficiency, durability and flexibility, and can provide users with a reliable high-temperature smoke exhaust solution.
Frequently Asked Questions
Q
What is the HTF series high-temperature fan primarily used for?
The HTF series fire-fighting high-temperature fan is primarily designed for smoke exhaust and ventilation in high-temperature environments, including high-rise buildings, underground garages, tunnels, and industrial drying furnaces. It plays a critical role in fire protection systems by quickly discharging high-temperature smoke during fire emergencies.
Q
What is the difference between HTF-I and HTF-II series fans?
The HTF-II series is a dual-speed variant that offers two operating speeds (e.g., 2900/1450 r/min or 1450/960 r/min) for each model size. This allows greater flexibility in air volume control and energy efficiency compared to the single-speed HTF-I series, making HTF-II suitable for applications that require variable airflow.
Q
What is the maximum airflow capacity available in the HTF series?
The largest model (Model 15) in the HTF-I series can deliver a traffic (airflow) range of 93,800–76,041 m³/h at 960 r/min, making it suitable for large-scale industrial and commercial ventilation requirements. The HTF-II Model 15 offers up to 83,800–76,041 m³/h at its high-speed setting.
Q
How do the HTF series fans help save energy?
The HTF series fans feature an efficient performance curve and stable operating characteristics that minimize unnecessary energy consumption. The HTF-II dual-speed models allow users to run the fan at a lower speed during normal ventilation, switching to high speed only when emergency smoke exhaust is required, which significantly reduces overall energy costs.
Q
Are HTF series fans suitable for extreme high-temperature environments?
Yes. The HTF series fans are manufactured using high-temperature resistant materials and advanced production processes, ensuring reliable and stable operation in extreme thermal environments. They are specifically engineered to handle the demands of fire smoke exhaust, where temperatures can reach very high levels for extended periods.
Q
How easy is it to install and maintain an HTF series fan?
The HTF series fans feature a rational structural design that simplifies both installation and routine maintenance. Users can carry out daily upkeep without specialized tools in most cases, ensuring the equipment remains in optimal working condition throughout its service life and minimizing downtime.