01
High Efficiency FZY Outer Rotor Axial Flow Fan - Energy Saving Solution from China Suppliers & Factory
Technical Parameters
| Model | Speed (r/min) |
Power (W) |
Traffic (m³/h) |
Total pressure (Pa) |
Noise dB(A) |
Voltage (V) |
Frequency (Hz) |
Horsepower (HP) |
Number of blades |
|---|---|---|---|---|---|---|---|---|---|
| FZY-2E200 | 2350 | 55 | 1050 | 180 | 65 | 220 | 50 | 0.07 | 6 |
| FZY-2D200 | 2400 | 50 | 1050 | 180 | 65 | 380 | 50 | 0.07 | 6 |
| FZY-4E200 | 1450 | 40 | 510 | 70 | 53 | 220 | 50 | 0.05 | 6 |
| FZY-4D200 | 1450 | 50 | 510 | 70 | 53 | 380 | 50 | 0.07 | 6 |
| FZY-2E250 | 2200 | 155 | 2100 | 200 | 69 | 220 | 50 | 0.21 | 5 |
| FZY-2D250 | 2100 | 110 | 2100 | 200 | 69 | 380 | 50 | 0.15 | 5 |
| FZY-4E250 | 1400 | 50 | 1300 | 80 | 55 | 220 | 50 | 0.07 | 6 |
| FZY-4D250 | 1400 | 50 | 1200 | 80 | 55 | 380 | 50 | 0.07 | 6 |
| FZY-2E300 | 2100 | 165 | 2700 | 240 | 69 | 220 | 50 | 0.22 | 5 |
| FZY-2D300 | 2150 | 135 | 2500 | 240 | 69 | 380 | 50 | 0.18 | 5 |
| FZY-4E300 | 1350 | 70 | 2200 | 110 | 61 | 220 | 50 | 0.1 | 6 |
| FZY-4D300 | 1400 | 80 | 2200 | 110 | 61 | 380 | 50 | 0.11 | 6 |
| FZY-2E350 | 2350 | 260 | 4250 | 270 | 72 | 220 | 50 | 0.35 | 5 |
| FZY-2D350 | 2400 | 285 | 4450 | 270 | 72 | 380 | 50 | 0.38 | 5 |
| FZY-4E350 | 1400 | 95 | 2850 | 140 | 65 | 220 | 50 | 0.13 | 5 |
| FZY-4D350 | 1400 | 100 | 2700 | 140 | 65 | 380 | 50 | 0.13 | 5 |
| FZY-2E400 | 2380 | 305 | 5830 | 280 | 76 | 220 | 50 | 0.41 | 5 |
| FZY-2D400 | 2420 | 295 | 5880 | 280 | 76 | 380 | 50 | 0.4 | 5 |
| FZY-4E400 | 1420 | 140 | 4150 | 150 | 68 | 220 | 50 | 0.2 | 5 |
| FZY-4D400 | 1400 | 115 | 4100 | 150 | 68 | 380 | 50 | 0.15 | 5 |
| FZY-4E500 | 1390 | 340 | 7100 | 200 | 74 | 220 | 50 | 0.45 | 5 |
| FZY-4D500 | 1350 | 215 | 6500 | 200 | 74 | 380 | 50 | 0.3 | 5 |
| FZY-4E600 | 1320 | 850 | 12400 | 260 | 78 | 220 | 50 | 1.13 | 5 |
| FZY-4D600 | 1350 | 820 | 12600 | 260 | 78 | 380 | 50 | 1.1 | 5 |
Frequently Asked Questions
What is the difference between "E" and "D" series models?
The primary distinction is the operating voltage. Models with "E" (e.g., FZY-2E200) operate on single-phase 220V power, while models with "D" (e.g., FZY-2D200) operate on three-phase 380V power at 50Hz frequency.
How do 2-pole and 4-pole motor models compare in performance?
Models designated with "2" (such as FZY-2E/2D) operate at high speeds between 2100 to 2420 r/min providing higher air pressure. Models designated with "4" (such as FZY-4E/4D) run at around 1320 to 1450 r/min, resulting in lower noise levels and reduced power consumption.
What is the range of air volume (traffic) offered by this series?
The airflow capacity ranges from 510 m³/h on the compact FZY-4E200 model up to 12,600 m³/h on the high-capacity industrial FZY-4D600 model.
What are the operating noise levels across the lineup?
Noise levels range from 53 dB(A) on quieter low-speed models (such as FZY-4E200 and FZY-4D200) up to 78 dB(A) on heavy-duty 600-size industrial units.
How many blades are equipped on these fan models?
Depending on the model size and aerodynamic configuration, the fans are built with either 5 or 6 precision-balanced blades to ensure optimal airflow and total pressure performance.
What horsepower (HP) ratings are available in this lineup?
The motors range from 0.05 HP (40W) on small configurations up to 1.13 HP (850W) on the large FZY-4E600 unit, catering to diverse commercial and industrial ventilation demands.