CY-16 China Oil Fume Purification Centrifugal Fan - High Efficiency, Low Noise, Factory Direct from Reliable Suppliers
Parameters
| Model | Speedr/min | PowerkW-P | Trafficm³/h | Total PressurePa | VoltageV | FrequencyHz | HorsepowerHP |
|---|---|---|---|---|---|---|---|
| 400 | 960 | 1.5-6 | 5753-6837 | 800-600 | 380 | 50 | 2 |
| 960 | 2.2-6 | 6212-8267 | 900-600 | 380 | 50 | 3 | |
| 400-I | 960 | 3-6 | 7150-11237 | 1000-700 | 380 | 50 | 4 |
| 450 | 960 | 4-6 | 7885-11995 | 1100-750 | 380 | 50 | 5.5 |
| 500 | 960 | 5.5-6 | 13150-18235 | 1200-900 | 380 | 50 | 7.5 |
| 560 | 960 | 7.5-6 | 14237-22675 | 1500-800 | 380 | 50 | 10 |
Frequently Asked Questions
Q1
What does the model number (e.g., 400, 450, 500) represent in the parameter table?
The model number typically refers to the fan's impeller diameter in millimeters. For example, Model 400 has an impeller diameter of 400 mm, while Model 560 has a diameter of 560 mm. Larger model numbers generally indicate higher airflow capacity and power output.
Q2
Why do some models (e.g., Model 400) have two rows of parameters?
Model 400 offers two power configurations — 1.5-6 kW and 2.2-6 kW — to accommodate different application requirements. Each configuration provides a different range of airflow (m³/h) and total pressure (Pa), allowing users to select the most suitable option for their ventilation system.
Q3
What is the operating voltage and frequency for all listed models?
All models in the parameter table operate at a standard voltage of 380V and a frequency of 50Hz, making them compatible with standard industrial three-phase power supplies commonly used in manufacturing and commercial ventilation applications.
Q4
How do I choose the right model based on traffic (airflow) requirements?
To select the correct model, calculate the required airflow volume (m³/h) for your space based on room volume and required air changes per hour (ACH). Then match this value to the traffic range listed in the parameter table. For example, if you need approximately 15,000 m³/h, Model 500 (13,150–18,235 m³/h) would be an appropriate choice.
Q5
What does "Total Pressure (Pa)" mean and why does it matter?
Total pressure (measured in Pascals) is the sum of static pressure and dynamic pressure within the fan system. It indicates the fan's ability to overcome resistance in the ductwork and ventilation system. A higher total pressure rating means the fan can push air through longer or more complex duct systems effectively.
Q6
What is the difference between Model 400 and Model 400-I?
Model 400-I is an enhanced version of the standard Model 400. It operates at a higher power range (3-6 kW vs. up to 2.2-6 kW), delivers greater airflow (7,150–11,237 m³/h), and supports a higher total pressure range (1,000–700 Pa). The "I" designation typically indicates an upgraded or improved variant designed for more demanding ventilation conditions.