01
CMF Series Low Noise Axial Fan - Two-Way Ventilation from China Suppliers and Factory for Efficient Airflow
Parameters
| Model | Speed (r/min) |
Power (kW-P) |
Traffic (m³/h) |
Total Pressure (Pa) |
Voltage (V) |
Frequency (Hz) |
Horsepower (HP) |
|---|---|---|---|---|---|---|---|
| 3.5 (14") | 2900 | 0.75-2 | 6942 | 354 | 220/380 | 50 | 0.5 |
| 1450 | 0.12-4 | 3471 | 89 | 220/380 | 50 | 0.12 | |
| 4 (16") | 2900 | 1.5-2 | 9312 | 476 | 220/380 | 50 | 2 |
| 1450 | 0.55-4 | 5780 | 149 | 220/380 | 50 | 0.75 | |
| 1630 | 6936 | 215 | 220/380 | 60 | |||
| 4.5 (18") | 1450 | 0.55-4 | 7652 | 206 | 220/380 | 50 | 0.75 |
| 1630 | 9183 | 297 | 220/380 | 60 | |||
| 960 | 0.18-6 | 5101 | 92 | 380 | 50 | 0.25 | |
| 5 (20") | 1450 | 0.75-4 | 10933 | 216 | 220/380 | 50 | 1 |
| 1630 | 13120 | 312 | 220/380 | 60 | |||
| 960 | 0.25-6 | 7289 | 96 | 380 | 50 | 0.33 | |
| 5.6 (22.4") | 1450 | 1.5-4 | 14523 | 307 | 220/380 | 50 | 2 |
| 960 | 0.37-6 | 9682 | 136 | 380/220 | 50 | 0.5 | |
| 6 (24") | 1450 | 2.2-4 | 18592 | 341 | 220/380 | 50 | 3 |
| 1630 | 22311 | 492 | 220/380 | 60 | |||
| 6.3 (25.2") | 1450 | 2.2-4 | 22421 | 356 | 220/380 | 50 | 3 |
| 7 (28") | 1450 | 3-4 | 24500 | 320 | 220/380 | 50 | 4 |
| 1630 | 29400 | 461 | 220/380 | 60 | |||
| 8 (32") | 1450 | 4-4 | 37807 | 435 | 380 | 50 | 5.5 |
| 1630 | 45370 | 627 | 380 | 60 | |||
| 9 (36") | 1450 | 5.5-4 | 51387 | 553 | 380 | 50 | 7.5 |
Technical Parameters of Booster Net Cover
| Model | Speed (r/min) |
Power (kW-P) |
Traffic (m³/h) |
Total Pressure (Pa) |
Voltage (V) |
Frequency (Hz) |
Horsepower (HP) |
|---|---|---|---|---|---|---|---|
| 4 (16") | 2900 | 1.5-2 | 9880 | 600 | 220/380 | 50 | 2 |
| 1450 | 0.55-4 | 6130 | 190 | 220/380 | 50 | 0.75 | |
| 5 (20") | 1450 | 0.75-4 | 11600 | 280 | 220/380 | 50 | 1 |
| 960 | 0.25-6 | 7800 | 130 | 380 | 50 | 0.33 |
Frequently Asked Questions
What is the advantage of using a Booster Net Cover?
The Booster Net Cover is designed to optimize airflow dynamics, resulting in increased air volume (traffic) and significantly higher total pressure compared to standard configurations with the same motor power.
Can these fans operate on both 50Hz and 60Hz power supplies?
Yes, multiple models support dual-frequency operation (50Hz / 60Hz) with 220V/380V voltage configurations. Speed and pressure outputs adjust accordingly based on the operating frequency (e.g., 1450 r/min at 50Hz vs. 1630 r/min at 60Hz).
How do I choose the correct fan model based on airflow requirements?
Identify the total volume of the target area and required air exchanges per hour to determine the required airflow in m³/h (Traffic). Then match it with the total pressure (Pa) to overcome duct or system resistance.
What is the difference between 2-pole, 4-pole, and 6-pole motor speeds?
Motor pole configurations determine rotational speed. 2-pole motors operate around 2900 r/min for high pressure, 4-pole motors run at 1450 r/min for balanced performance, and 6-pole motors operate at 960 r/min for quiet, low-speed applications.
Are customized voltage ratings available for overseas installations?
Standard configurations cover 220V single-phase and 380V three-phase systems. Custom windings for specific industrial standards such as 415V, 440V, or 480V can be accommodated upon request.