Parameters
| Model | Speed (r/min) |
Power (kW-P) |
Traffic (m³/h) |
Total pressure (Pa) |
Voltage (V) |
Frequency (Hz) |
Horsepower (HP) |
|---|---|---|---|---|---|---|---|
| 2.8C | 2900 | 1.1-2 | 1131-2356 | 994-606 | 220/380 | 50 | 1.5 |
| 2900 | 1.5-2 | 1200-2516 | 1050-640 | 220/380 | 50 | 2 | |
| 3.2C | 2900 | 1.5-2 | 1688-3517 | 1300-792 | 220/380 | 50 | 2 |
| 2200 | 0.75-2 | 1483-2273 | 726-579 | 220/380 | 50 | 1 | |
| 3.6C | 2900 | 3-2 | 2664-5268 | 1578-989 | 220/380 | 50 | 4 |
| 2200 | 1.5-2 | 2310-3434 | 881-723 | 220/380 | 50 | 2 | |
| 2900 | 5.5-2 | 4012-7419 | 2014-1320 | 220/380 | 50 | 7.5 | |
| 4C | 2300 | 2.2-2 | 3573-5491 | 1238-917 | 220/380 | 50 | 3 |
| 2000 | 1.5-2 | 3107-4775 | 936-694 | 220/380 | 50 | 2 | |
| 2900 | 7.5-2 | 5712-10562 | 2554-1673 | 220/380 | 50 | 10 | |
| 4.5C | 2300 | 4-2 | 5088-7819 | 1570-1163 | 220/380 | 50 | 5.5 |
| 2000 | 3-2 | 4428-6799 | 1187-879 | 220/380 | 50 | 4 | |
| 1700 | 2.2-2 | 3761-5779 | 858-635 | 220/380 | 50 | 3 | |
| 2900 | 15-2 | 7728-15445 | 3187-2019 | 220/380 | 50 | 20.5 | |
| 5C | 2300 | 7.5-2 | 7022-11363 | 1978-1468 | 220/380 | 50 | 10 |
| 2000 | 5.5-2 | 6106-9881 | 1495-1110 | 220/380 | 50 | 7.5 | |
| 1700 | 3-2 | 5190-8399 | 1080-802 | 220/380 | 50 | 4 | |
| 2600 | 18.5-2 | 12734-17824 | 3209-2541 | 220/380 | 50 | 25 | |
| 5.6C | 2600 | 15-2 | 9734-19466 | 3213-2035 | 220/380 | 50 | 20.5 |
| 2300 | 11-2 | 8610-17220 | 2514-1593 | 220/380 | 50 | 15 | |
| 2000 | 7.5-2 | 7487-14914 | 1901-1204 | 220/380 | 50 | 10 | |
| 1700 | 5.5-2 | 6364-12728 | 1373-870 | 220/380 | 50 | 7.5 | |
| 1400 | 3-4 | 5242-10482 | 931-590 | 220/380 | 50 | 4 | |
| 6C | 2240 | 15-2 | 10314-20628 | 2734-1733 | 220/380 | 50 | 20.5 |
| 2000 | 11-2 | 9209-18418 | 2176-1380 | 220/380 | 50 | 15 | |
| 1800 | 7.5-2 | 8288-16576 | 1790-1116 | 220/380 | 50 | 10 | |
| 1600 | 5.5-4 | 7367-14734 | 1689-881 | 220/380 | 50 | 7.5 | |
| 1250 | 3-4 | 5756-11511 | 846-537 | 220/380 | 50 | 4 | |
| 6.3C | 2200 | 18.5-2 | 15342-21474 | 2908-2303 | 220/380 | 50 | 25 |
| 1900 | 11-2 | 13250-18546 | 2169-1718 | 220/380 | 50 | 15 | |
| 1600 | 7.5-2 | 11158-15618 | 1538-1218 | 220/380 | 50 | 10 | |
| 1400 | 5.5-2 | 1020-13500 | 1080-1320 | 220/380 | 50 | 7.5 | |
| 1300 | 4-4 | 9066-12689 | 1015-804 | 220/380 | 50 | 5.5 | |
| 7.1C | 1800 | 18.5-4 | 15736-25265 | 2422-1801 | 220/380 | 50 | 25 |
| 1600 | 15-4 | 13987-22635 | 1914-1423 | 220/380 | 50 | 20.5 | |
| 1450 | 11-4 | 12676-20513 | 1573-1168 | 220/380 | 50 | 15 | |
| 1200 | 5.5-4 | 10490-16976 | 1076-800 | 220/380 | 50 | 7.5 | |
| 960 | 3-4 | 8392-13581 | 689-512 | 220/380 | 50 | 4 | |
| 1800 | 30-4 | 19646-25240 | 3134-3032 | 220/380 | 50 | 41 | |
| 37-4 | 28105-36427 | 2920-2302 | 220/380 | 50 | 50 | ||
| 1600 | 22-4 | 17463-22435 | 2478-2390 | 220/380 | 50 | 30 | |
| 30-4 | 24982-32380 | 2303-1816 | 220/380 | 50 | 41 | ||
| 1250 | 11-4 | 13643-25297 | 1507-1106 | 220/380 | 50 | 15 | |
| 8C | 1120 | 7.5-4 | 12224-15705 | 1209-1166 | 220/380 | 50 | 10 |
| 11-4 | 17487-22666 | 1124-887 | 220/380 | 50 | 15 | ||
| 1000 | 5.5-4 | 10914-14022 | 963-929 | 220/380 | 50 | 7.5 | |
| 7.5-4 | 15614-20237 | 895-707 | 220/380 | 50 | 10 | ||
| 900 | 4-4 | 9823-12620 | 779-752 | 220/380 | 50 | 5.5 | |
| 5.5-4 | 14052-18213 | 725-572 | 220/380 | 50 | 7.5 | ||
| 800 | 3-4 | 8732-16190 | 615-452 | 220/380 | 50 | 4 | |
| 710 | 3-4 | 7749-14368 | 485-356 | 220/380 | 50 | 4 | |
| 10C | 1250 | 37-4 | 34863-48979 | 2737-1877 | 220/380 | 50 | 50 |
| 1120 | 30-4 | 31237-43722 | 1902-1505 | 220/380 | 50 | 41 | |
| 1000 | 18.5-4 | 27890-39038 | 1514-1199 | 220/380 | 50 | 25 | |
| 900 | 15-4 | 25101-35134 | 1225-970 | 220/380 | 50 | 20.5 | |
| 800 | 11-4 | 22312-31230 | 967-766 | 220/380 | 50 | 15 | |
| 710 | 7.5-4 | 19802-27717 | 761-603 | 220/380 | 50 | 10 | |
| 630 | 5.5-4 | 17571-24594 | 599-475 | 220/380 | 50 | 7.5 | |
| 560 | 4-4 | 15618-21861 | 473-375 | 220/380 | 50 | 5.5 | |
| 12C | 1120 | 75-4 | 53978-75552 | 2746-2172 | 220/380 | 50 | 102 |
| 1000 | 45-4 | 48195-60397 | 2185-1969 | 220/380 | 50 | 61 | |
| 55-4 | 63953-67457 | 1859-1729 | 220/380 | 50 | 75 | ||
| 900 | 37-6 | 43375-60712 | 1767-1399 | 220/380 | 50 | 50 | |
| 800 | 22-4 | 38556-41973 | 1385-1376 | 220/380 | 50 | 30 | |
| 30-4 | 45391-53996 | 1321-1104 | 220/380 | 50 | 41 | ||
| 710 | 18.5-6 | 34218-47895 | 1097-869 | 220/380 | 50 | 25 | |
| 630 | 15-6 | 30362-42498 | 863-684 | 220/380 | 50 | 20.5 | |
| 560 | 7.5-4 | 26989-29381 | 682-673 | 220/380 | 50 | 10 | |
| 11-6 | 31774-37776 | 646-540 | 220/380 | 50 | 15 | ||
| 500 | 7.5-4 | 24907-33728 | 543-430 | 220/380 | 50 | 10 |
Frequently Asked Questions
What is the significance of the "Total pressure" parameter?
Total pressure (measured in Pa) indicates the fan's capability to overcome system resistance. Selecting a model with the correct total pressure ensures efficient airflow through your ductwork or ventilation system.
How does "Traffic" (m³/h) affect fan selection?
"Traffic" refers to the volumetric flow rate or airflow capacity. You should choose a model that meets or exceeds the required air volume for your specific industrial application to ensure proper ventilation or cooling.
Are the voltage and frequency suitable for standard industrial use?
Yes, all models listed in the parameters table operate at a standard industrial voltage of 220/380V and a frequency of 50Hz, making them highly compatible with standard three-phase electrical systems.
What does the Power (kW-P) rating indicate?
The Power rating shows the required motor capacity in kilowatts. Models with higher rotational speeds and larger airflow capacities generally require a higher power rating to maintain optimal performance without overloading the motor.
Why are there multiple speeds (r/min) for the same model?
Different rotational speeds allow the same basic fan model to deliver varying levels of airflow and pressure. Lower speeds are typically more energy-efficient and quieter, while higher speeds provide maximum performance for demanding tasks.